-40%

1Phase to 3Phase Converter, MY-PS-20, Best for 15HP(11KW) 45 Amp 200V~240V Motor

$ 368.54

Availability: 13 in stock
  • Item must be returned within: 60 Days
  • Type: Digital Static Phase Converter
  • MPN: MY-PS-20
  • All returns accepted: Returns Accepted
  • Continuous/Minimum Load Horsepower: 15HP
  • Operating Frequency: 50 Hz - 60 Hz
  • Output Voltage: 200 V - 240 V
  • Input Current: 45 A
  • Brand: D.P.S.
  • Input Voltage: 200 V - 240 V
  • Condition: New
  • Restocking Fee: No
  • Mounting Style: Stand Alone
  • Suitable Load Types: 1 year warranty
  • Modified Item: No
  • Starting/Maximum Load Horsepower: 20HP
  • Horsepower: 15 hp
  • Output Current: 45 A
  • Country/Region of Manufacture: Korea, Republic of
  • Conversion Type: 1 to 3 Phase
  • Return shipping will be paid by: Buyer
  • Custom Bundle: No
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description


    In order to your convenience for your questions, please refer the following messengers.

    WhatsApp : +82 10 5695 1514

    Delivery time: Around 4~5 business days(DHL or FedEx courier service)

    Before ordering our phase converter, please give us the information about your motor purpose to recommend a suitable phase
    converter to you. Also, please note the below points carefully.
    1.
    MY-PS-20 model could be used at 15HP motor.
    (11KW, 45 amps)
    2.
    It should only be used for one motor per one DPS
    .
    The use of multiple motors is not allowed in our DPS.
    3.  The input/output voltage of our DPS is 200v~240v.
    4.
    Our DPS is designed to be suitable for use in motor.
    5.  The efficiency is around 90~95%.
    6.
    The voltage of motor should be 200v~240v. If the voltage of your motor is 380v or 440v, you should change the wire of motor to 200v~240v purpose to connect with output of our DPS.
    7.
    The thickness of wires must be suitable for amperes.
    8.
    Only single phase motor brake is allowed.(Three phase motor brake is not working at our DPS)
    9.
    You could check three phase on the output of DPS when your motor is running. If your motor is not running, you could not check three phase from output of DPS.
    10.
    If your motor has magnetic starter, or electronic switch, or brake, the operating wires of this device should be connected on “U” and “W” of output of our phase converter.
    Thus, if your motor is not running well or the motor is reversing, you should turn off the power immediately and you have to switch the wires on output(U, V, W) of our phase converter. Actually, when you connect the wires from output of phase converter to your motor, you could succeed in first time, or second time, or third time.
    A. Detail information
    1. Capacity :
    Suitable for 15HP motor(11KW, 45 amps)
    2. Frequency : 50/60 Hz
    3. Dimension(inch) : 13x17x7(WxHxD)
    4. Net Weight : 4.9kg(10.8lbs)
    5. Voltage : 200V ~ 240V
    B. Features
    1. Drive 3 phase motor with single phase
    2. The failure rate was even lower frequency operation
    3. Excellent start-up torque
    4. The size is small & easy to install
    5. Semi-permanent life time
    6. Energy saving effect
    7. Stable in humid, dust, vibration and impact
    8. Three phase motor could be used at your home
    * Features of 3 phase motor
    Compared with 1 Phase Motor
    =>
    Low failure rate, Small size, High efficiency, Affordable price
    C. Notices
    1. The product shall be used only 3 phase 200V ~ 240V motor.
    2. Use only one motor which suits the capacity range of this product.(1:1)
    3. If the motor overheats, check whether the current is correct as shown on the motor nameplate.(Within 85% of rated)
    4. When checking the D.P.S. voltage only, two phase voltage are output, and three phase voltage are output when the motor is running.
    5. If you use a motor for a large load condition, use the D.P.S product with one rating higher.
    Do not use it with higher than one rating. (This may cause motor failure)
    6. Motor brake must be of single phase only.(A brake for 3 phase does not work)
    7. Regarding operating cables of
    electromagnetic switches, brake, magnet
    , you should connect two wires to U and W positions of DPS's output.
    D. Specifications
    1. Application range : 3 phase 220v motor type
    2. Rated voltage : 3 phase 220v
    ±
    10%
    3. How to convert : Relay control circuit for three-phase driving
    4. Ambient temperature : -10 ~ 50
    °
    C
    5. Enclosure : Open type(IP54)
    6. Insulation resistance : 100M

    or higher based on 500V DC MEGA
    7. Withstanding voltage : Within 85% of motor rated current
    E. Application
    - All products driven by 3 phase motors
    - All motors for industrial and domestic purpose
    - High pressure washer
    - Hoists
    - Compressors
    - Conveyor motors
    - Agitators
    - Food processing machines
    - Hydraulic motors
    - Document cutter
    - Meat slicers
    - Agricultural machines
    - Woodworking machines
    - Portable air conditioners
    - Machines for pumping
    - Blowers
    - Ceramics machines
    - Fan motors
    - Portable packaging machines
    - Cutters, etc.
    * These products can be connected for use quickly and easily everywhere.
    F. Instances of D.P.S.
    - Conventional 1 phase motors which have been used at home and abroad have problems that centrifugal force switch contacts wear at start-up, fires occurs due to sparks, and production cost increases compared to 3 phase motors.
    Digital phase converter is a device to supplement such problems in a perfect way, and had a compact size for easy installation, and a wide application in the machines requiring strong start-up torque. In addition, 3 phase motors can be driven at your home.